127 research outputs found

    Microwave Radar-Based Breast Cancer Detection:Imaging in Inhomogeneous Breast Phantoms

    Get PDF
    This document is made available in accordance with publisher policies. Please cite only the published version using the reference above. Full terms of use are available

    Radar-based breast cancer detection using a hemispherical antenna array - experimental results

    Get PDF
    This document is made available in accordance with publisher policies. Please cite only the published version using the reference above. Full terms of use are available

    Development and application of a UWB radar system for breast imaging

    Get PDF

    Towards contrast enhanced breast imaging using ultra-wideband microwave radar system

    Get PDF

    Breast surface reconstruction algorithm for a multi-static radar-based breast imaging system

    Get PDF

    Short GSM mobile phone exposure does not alter human auditory brainstem response

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>There are about 1.6 billion GSM cellular phones in use throughout the world today. Numerous papers have reported various biological effects in humans exposed to electromagnetic fields emitted by mobile phones. The aim of the present study was to advance our understanding of potential adverse effects of the GSM mobile phones on the human hearing system.</p> <p>Methods</p> <p>Auditory Brainstem Response (ABR) was recorded with three non-polarizing Ag-AgCl scalp electrodes in thirty young and healthy volunteers (age 18–26 years) with normal hearing. ABR data were collected before, and immediately after a 10 minute exposure to 900 MHz pulsed electromagnetic field (EMF) emitted by a commercial Nokia 6310 mobile phone. Fifteen subjects were exposed to genuine EMF and fifteen to sham EMF in a double blind and counterbalanced order. Possible effects of irradiation was analyzed by comparing the latency of ABR waves I, III and V before and after genuine/sham EMF exposure.</p> <p>Results</p> <p>Paired sample t-test was conducted for statistical analysis. Results revealed no significant differences in the latency of ABR waves I, III and V before and after 10 minutes of genuine/sham EMF exposure.</p> <p>Conclusion</p> <p>The present results suggest that, in our experimental conditions, a single 10 minute exposure of 900 MHz EMF emitted by a commercial mobile phone does not produce measurable immediate effects in the latency of auditory brainstem waves I, III and V.</p

    A 3D Human Posture Approach for Activity Recognition Based on Depth Camera

    Get PDF
    Human activity recognition plays an important role in the context of Ambient Assisted Living (AAL), providing useful tools to improve people quality of life. This work presents an activity recognition algorithm based on the extraction of skeleton joints from a depth camera. The system describes an activity using a set of few and basic postures extracted by means of the X-means clustering algorithm. A multi-class Support Vector Machine, trained with the Sequential Minimal Optimization is employed to perform the classification. The system is evaluated on two public datasets for activity recognition which have different skeleton models, the CAD-60 with 15 joints and the TST with 25 joints. The proposed approach achieves precision/recall performances of 99.8 % on CAD-60 and 97.2 %/91.7 % on TST. The results are promising for an applied use in the context of AAL

    Assessment of potential effects of the electromagnetic fields of mobile phones on hearing

    Get PDF
    BACKGROUND: Mobile phones have become indispensable as communication tools; however, to date there is only a limited knowledge about interaction between electromagnetic fields (EMF) emitted by mobile phones and auditory function. The aim of the study was to assess potential changes in hearing function as a consequence of exposure to low-intensity EMF's produced by mobile phones at frequencies of 900 and 1800 MHz. METHODS: The within-subject study was performed on thirty volunteers (age 18–30 years) with normal hearing to assess possible acute effect of EMF. Participants attended two sessions: genuine and sham exposure of EMF. Hearing threshold levels (HTL) on pure tone audiometry (PTA) and transient evoked otoacoustic emissions (TEOAE's) were recorded before and immediately after 10 min of genuine and/or sham exposure of mobile phone EMF. The administration of genuine or sham exposure was double blind and counterbalanced in order. RESULTS: Statistical analysis revealed no significant differences in the mean HTLs of PTA and mean shifts of TEOAE's before and after genuine and/or sham mobile phone EMF 10 min exposure. The data collected showed that average TEOAE levels (averaged across a frequency range) changed less than 2.5 dB between pre- and post-, genuine and sham exposure. The greatest individual change was 10 dB, with a decrease in level from pre- to post- real exposure. CONCLUSION: It could be concluded that a 10-min close exposure of EMFs emitted from a mobile phone had no immediate after-effect on measurements of HTL of PTA and TEOAEs in young human subjects and no measurable hearing deterioration was detected in our study
    • …
    corecore